Fox Shox Dial Indicator Attachment for Plate Lift Measurement
BTI part #: |
FX2316 |
vendor part #: |
803-00-806 |
UPC: |
611056143728 |
description: |
dial indicator attachment, plate lift measurement |
compatibility: |
iCD/CTD Dish |
|
N O T E
dish shock dial indicator attachment for plate lift measurement
|
|
|
- For measuring lockout plate lift
- For Lever models: when switching from Firm to Medium modes, Lockout plate lift should measure between 0.030-0.047in (0.77-1.19mm)
- For Remote models: when switching from Firm to Open modes, Lockout plate lift should measure between 0.072-0.090in (1.83-2.29mm)
- 1 or 2 spacers (044-20-035 or 044-10-035) may be added or removed from the lockout shim stack to adjust lockout plate lift to within approved range
|
|
|
|